Equipment Technical Parameters
1. Conventional size table, can be customized according to customer requirements
Model | Inner diameter size (unit:mm) D*W*H | Outer diameter size (unit:mm) | Power | Temperature range | Volume |
XCY-1001 | 500×600×600 | 750×1000×1250 | 5KW | rt+10~250℃ | 180L |
XCY-1002 | 500×600×1000 | 750×1000×1650 | 8KW | rt+10~250℃ | 300L |
XCY-2002 | 600×860×1000 | 850×1260×1650 | 12KW | rt+10~250℃ | 516L |
XCY-2004 | 1000×1000×1000 | 1250×1400×1650 | 18KW | rt+10~250℃ | 1000L |
XCY-2005 | 1000×1200×1600 | 1250×1600×2250 | 25KW | rt+10~250℃ | 1920L |
2. Shell temperature: the outside wall temperature of the furnace does not exceed room temperature + 15 ℃;
3. Using Japanese Omron temperature controller, temperature fluctuation ±1 ℃, furnace temperature difference ±3℃.
4. Power supply: three-phase five-wire system, 380V, 50HZ;
5. Customizable trolley according to user requirements.
6. Widely used in drying, dehydration, curing, aging testing, high temperature melting, constant temperature and other industries such as automotive parts, plastics, hardware, electronics, and chemical industry.