Technical Parameters of Equipment
1. There are a total of 40 aging chambers, with a single chamber inner diameter of D600*W600*H250mm (customized according to user calibration requirements)
2. Temperature: constant temperature adjustable from 40℃ to 100℃, outer shell temperature: the temperature of the furnace outer wall does not exceed room temperature + 15℃;
3. Temperature fluctuation ±1℃, temperature difference inside the furnace ±3℃, large air volume hot air circulation inside the chamber.
4. Power supply: three-phase five-wire system, 380V, 50HZ;
5. Heating source: electric,
6. Siemens screen + Siemens PLC control system
7. Each compartment has its own automatic sliding door
8. Widely used in drying, dehydration, curing, aging testing, high temperature melting, constant temperature, and other industries such as automotive parts, plastic, hardware, electronic products, and chemical engineering.