XCY-SD-6014 Four channel heating and cooling furnace

  • 产品详情


04.jpeg

Equipment technical parameters

1. External dimensions (approximately): L12000 * W6000 * H2000mm; The heating zone is 6000mm long, and the cooling zone is 3000mm long,

1. Shell temperature: The temperature of the outer wall of the furnace shall not exceed room temperature+15 ℃;

2. Independent conveying through four channels on the left and right, with 40 rotors in the heating furnace and 20 rotors in the cooling furnace

3. Curing temperature 180 ℃, cooled to room temperature and taken out of the furnace

4. The temperature inside the furnace can be adjusted from room temperature to 250 ℃.

5. Power supply: three-phase five wire system, 380V, 50HZ;

6. Power: approximately 120KW;